Testing (Indication: Full LED flashing):
The “testing” phase is the phase where the battery is tested for a defect battery cell.
|
|
 |
Soft charge (indikation: lysdioden “Discharged” blinker):
Den “bløde opladningsfase” benyttes, når batteriet er kraftigt afladt.Batteriet oplades blødt (ved 11,6 V), indtil det kan tåle normal opladning.
|
|
.jpg) |
Desulphation (Indication: Low LED flashing):
The “desulphation” phase is used if the battery has not been used in a longer period.
|
|
 |
Bulk charging (Indication: Low LED flashing):
The “bulk” phase is the phase where the battery under a constant current is charged up to app. 85% of the full capacity.
|
|
 |
Absorption (Indication: Medium LED flashing):
The “absorption” phase is the phase where the battery under a constant voltage is charged up to app. 98% of the full capacity.
|
|
|
Maintenance (Indication: Full LED constant):
The purpose with “maintenance” phase is to keep the battery at 100% over a long period of time. The charger is at all time measuring the voltage and when it goes below 12,6 V it will start charging the battery.
|
| |
|
|
| |
|
|